gamewell-fci 12 clintonville road, northford, ct 06472-1610 usa ? tel: (203) 484-7161 ? fax: (203) 484-7118 specifications are for information only, are not intended for installa tion purposes, and are subject to change without notice. no responsibility is assumed by gamewell-fci for their use. ?2013 by honeywell international inc. all rights reserved. www.gamewell-fci.com 9020-0596 rev. k page 1 of 1 anu-48 anu-48 led driver module approved fm 3017416 7165-1703:0125 fdny: coa #6077 s1869 signaling mea approved approved city of chicago city of denver approved class 1 class 2 high rise description ? the gamewell-fci, anu-48 led driver module is a remote annunciator that is used in conjunction with the following systems. ? e3 series ? expandable emergency evacuation system ? e3 series combined fire and mass notification system ? e3 series broadband voice evacuation system ? s3 series small addressable fire alarm control panel ? netsolo ? system it provides output for up to 8 remote panel switches and 48 remote leds, contributing to the versatility and flexibility of the gamewell-fci system. ? the switches may be programmed to operate as any of the following predefined functions: ? speaker circuit switch ? fire fighter phone switch ? auxiliary control switch usi ng a bank of two switches (use one switch for each on-off-auto function) in addition, the switches may be programmed to operate with the following custom-defined functions: ? system silence ? alarm acknowledge ? trouble acknowledge ? lamp test ? alarm tone on ? manual select ? drill and system reset/led the output is also provided for the following leds: ? alarm ? system trouble ? supervisory ? power fault ? system silenced ? nac #1 silenced ? nac #2 silenced ? while underwriters laborator ies standards only address testing at ambient temperatur es down to 32 f, the anu- 48 is factory mutual approved for an ambient temperature of -40 f/c (non-condensing). when it is powered exter- nally, each driver circuit pr ovides a maximum of .050 amp with a maximum of 2.4 amperes per anu-48 module. ? note: if you install more than four anu-48 modules, an external regulated and class 2 power-limited power sup- ply, listed for use with the fire protective signaling units, is required. ? specifications operating voltage: 24 vdc resettable operating current: 0.011 amp* operating temperature: 32 to 120 f (0 to 49 c) relative humidity: 0 to 93%, (non-condensing) at 90 f (32 c) *add .003 amp for any led to be lit for any condition when pow- ered internally. when powered externally, each driver circuit pro- vides a maximum of 0.050 amp with a maximum of 2.4 amps. per anu-48 sub-assembly (48) circuits. e3 series ? and netsolo ? are registered trademarks of honeywell international inc. ul ? is a registered trademark of underwriters laboratories inc. features ? listed under ul ? standard 864, 9th edition. ? listed under ul ? standard ul2572 for mass notification. ? includes input for eight software programmable switches, maintained on momentary contact. ? provides output for up to 48 remote leds or driver cir- cuits. ? the ini-vg series, ili-mb-e3/ili95-mb-e3 or slp (smart loop panel) can support up to 16 anu-48 led driver modules or asm-16 swit ch modules for a total of 128 switches and 768 leds. ? installed up to 3,000 feet (914.4 m) from the control panel, and up to 15 additional annunciators can be connected. ? adaptable to be mounted in any remotely located ul listed annunciator enclosure listed with the anu-48. ? ordering information ? part number description 1100-0503 remote led driver module anu-48
|